Bb-electronics FOSTCDRI-INV - Quick Start Guide Manual de usuario

Busca en linea o descarga Manual de usuario para Accesorios de comunicación Bb-electronics FOSTCDRI-INV - Quick Start Guide. B&B Electronics FOSTCDRI-INV - Quick Start Guide User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 3
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
If you wish to enable termination, refer to:
http://www.bb-elec.com/technical_library.asp
For baud rates not listed above, refer to:
http://www.bb-elec.com/technical_library.asp
FO RX
FO TX
FO RX
FO TX
FO RX
FO TX
FO RX
FO TX
FO TX
FO RX
SW 1-12
OFF
SW 1-12
OFF
SW 1-12
ON
SW 1-12
ON
SW 1-12
ON
Set DIP Switches for Baud Rate
Set DIP Switches for RS-232/422/485 Mode
Wire the Converter
OFF = Point-to-Point
LED Indicators
Set DIP Switch 12
Product Overview
Serial Terminal Block Settings
Conversion
& Timeout
Point-to-Point Multi-drop Ring
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
ON = Multi-drop Ring
D
TD
RD
GND
A
E
B
C
TD
RD
GND
Computer
Your DeviceFOSTCDRi
Field Device
Your DeviceFOSTCDRi
DTE
DCE
D
A
E
B
C
Additional tech notes on RS-422/485 connections are located at:
http://www.bb-elec.com/technical_library.asp
D
A
E
B
C
RS-485 2-Wire
Your DeviceFOSTCDRi
RS-485 4-Wire
Your DeviceFOSTCDRi
D
A
E
B
C
RS-232
RS-422/485
RD B (+)
RD A (-)
GND
TD B (+)
TD A (-)
TD/RD B (+)
TD/RD A (-)
GND
Additional tech notes on RS-232 DTE/DCE connections
are located at: http://www.bb-elec.com/technical_library.asp
• Input Voltage 10-48 VDC (56 VDC max)
• Power Consumption 0.5 W (Typical),
1.3W Max
• Duplex multi-mode ber with ST connectors
• Fiber cable specs needed:
62.5/125 micro-meter, 820 nm wavelength
Power the Converter
• Input Voltage 10-48 VDC (56 VDC max)
• Power Consumption 0.5 W (Typical), 1.3W Max
Multi-drop mode allows one serial device to communicate
with up to 31 others around a ber optic ring. Data will repeat
around the ring until it nally reaches its source. When the
data is received by the originator, timeout circuitry will prevent
it from being re-transmitted.
Switch Selectable Timeouts
Baud
DIP Switch Position Timeout
8 9 10 11
9.6 K
OFF OFF OFF ON 1.3 ms
19.2 K
OFF OFF ON OFF .56 ms
38.4 K
OFF ON OFF OFF .27 ms
57.6 K
ON OFF OFF OFF .22 ms
76.8 K
ON OFF ON ON .14 ms
115.5 K
ON ON ON OFF .10 ms
DIP Switch Position
Mode 1 2 3 4 5 6 7
RS-485 2-Wire, Half-duplex ON ON ON ON OFF ON OFF
RS-485 4-Wire, Full-duplex ON OFF OFF
OFF
OFF OFF OFF
RS-422 Full-duplex OFF OFF OFF OFF OFF ON OFF
Terminal
RS-485
2-Wire
RS-422/485
4-Wire
RS-232
A GND GND GND
B Data B (+) RD B (+) ******
C Data A (-) RD A (-)
RS-232 Data
Input
D ****** TD B (+) ******
E ****** TD A (-)
RS-232 Data
Output
Receive Red, ON when data received on ber
Transmit Red, ON when data sent on ber
Power Red, ON when power applied
Maximum Converters in a Fiber Ring
Baud Rate RS-232 RS-422/485
19.2 kbps and lower 32 32
38.4 kbps 16 24
115.2 kbps 2 8
1
2
3
5
6
Multi-drop Mode
4
Vista de pagina 0
1 2 3

Indice de contenidos

Pagina 1 - Product Overview

If you wish to enable termination, refer to: http://www.bb-elec.com/technical_library.aspFor baud rates not listed above, refer to: http://www.bb-el

Pagina 2 - FOSTCDRi & FOSTCDRi-INV

TroubleshootingWhen using Point to Point mode can I set one of the FOSTCDRi’s as 232 and the other as 422 or 485? Yes. What do the TX Bias and RX B

Pagina 3

Industrial Serial to Multi-mode Fiber ConvertersFOSTCDRi & FOSTCDRi-INVInformation—UL Class 1 Div 21. Power, input /output (I/O) wiring must be in

Comentarios a estos manuales

Sin comentarios