If you wish to enable termination, refer to:
http://www.bb-elec.com/technical_library.asp
For baud rates not listed above, refer to:
http://www.bb-elec.com/technical_library.asp
FO RX
FO TX
FO RX
FO TX
FO RX
FO TX
FO RX
FO TX
FO TX
FO RX
SW 1-12
OFF
SW 1-12
OFF
SW 1-12
ON
SW 1-12
ON
SW 1-12
ON
Set DIP Switches for Baud Rate
Set DIP Switches for RS-232/422/485 Mode
Wire the Converter
OFF = Point-to-Point
LED Indicators
Set DIP Switch 12
Product Overview
Serial Terminal Block Settings
Conversion
& Timeout
Point-to-Point Multi-drop Ring
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
Conversion
& Timeout
FOSTCDRi
ON = Multi-drop Ring
D
TD
RD
GND
A
E
B
C
TD
RD
GND
Computer
Your DeviceFOSTCDRi
Field Device
Your DeviceFOSTCDRi
DTE
DCE
D
A
E
B
C
Additional tech notes on RS-422/485 connections are located at:
http://www.bb-elec.com/technical_library.asp
D
A
E
B
C
RS-485 2-Wire
Your DeviceFOSTCDRi
RS-485 4-Wire
Your DeviceFOSTCDRi
D
A
E
B
C
RS-232
RS-422/485
RD B (+)
RD A (-)
GND
TD B (+)
TD A (-)
TD/RD B (+)
TD/RD A (-)
GND
Additional tech notes on RS-232 DTE/DCE connections
are located at: http://www.bb-elec.com/technical_library.asp
• Input Voltage 10-48 VDC (56 VDC max)
• Power Consumption 0.5 W (Typical),
1.3W Max
• Duplex multi-mode ber with ST connectors
• Fiber cable specs needed:
62.5/125 micro-meter, 820 nm wavelength
Power the Converter
• Input Voltage 10-48 VDC (56 VDC max)
• Power Consumption 0.5 W (Typical), 1.3W Max
Multi-drop mode allows one serial device to communicate
with up to 31 others around a ber optic ring. Data will repeat
around the ring until it nally reaches its source. When the
data is received by the originator, timeout circuitry will prevent
it from being re-transmitted.
Switch Selectable Timeouts
Baud
DIP Switch Position Timeout
8 9 10 11
9.6 K
OFF OFF OFF ON 1.3 ms
19.2 K
OFF OFF ON OFF .56 ms
38.4 K
OFF ON OFF OFF .27 ms
57.6 K
ON OFF OFF OFF .22 ms
76.8 K
ON OFF ON ON .14 ms
115.5 K
ON ON ON OFF .10 ms
DIP Switch Position
Mode 1 2 3 4 5 6 7
RS-485 2-Wire, Half-duplex ON ON ON ON OFF ON OFF
RS-485 4-Wire, Full-duplex ON OFF OFF
OFF
OFF OFF OFF
RS-422 Full-duplex OFF OFF OFF OFF OFF ON OFF
Terminal
RS-485
2-Wire
RS-422/485
4-Wire
RS-232
A GND GND GND
B Data B (+) RD B (+) ******
C Data A (-) RD A (-)
RS-232 Data
Input
D ****** TD B (+) ******
E ****** TD A (-)
RS-232 Data
Output
Receive Red, ON when data received on ber
Transmit Red, ON when data sent on ber
Power Red, ON when power applied
Maximum Converters in a Fiber Ring
Baud Rate RS-232 RS-422/485
19.2 kbps and lower 32 32
38.4 kbps 16 24
115.2 kbps 2 8
1
2
3
5
6
Multi-drop Mode
4