6 LinkLoss, FiberAlert and Link Fault Pass-Through McPIM TP/FO and McLIM TX/FX and TX/SX include the following features: • FO/FX LinkLoss (a.k.a. &qu
7 Link Integrity During normal operation, link integrity pulses are transmitted by all point-to-point Ethernet devices. When an B&B Electronics m
8 Link Fault Pass Through Link Fault Pass Through (LFPT) is a troubleshooting feature that combines TX and FX LinkLoss from both the local and remote
9 Pulsing FiberAlert Pulsing FiberAlert minimizes the problems associated with the loss of one strand of fiber. If a strand is unavailable, the devi
10 Configure LinkLoss and FiberAlert with separate 3-pin jumper blocks or DIP Switches located at various positions depending on module and board type
11 Configure Auto Negotiation on 100 Mbps Modules with a 3-pin jumper block located on the module’s PCB or DIP Switch, depending on the Model. Refer
12 NOTE Media converter chassis ship with all but one media conversion module slot covered with “blank” brackets. Be sure to keep unused slots covere
13 Power Supply Installation When installing a redundant power supply module into a powered-on 12-Slot chassis, B&B Electronics recommends setting
14 LEDs on McPIM TP/FO (-10) The LED functions on McPIM TP/FO (-10) are as follows: FO LINK/ACT Glows green when link is established on the FO port;
15 TX ACTIVITY Glows amber when data is being passed on the TX port. LEDs on McGigabit and McLIM TX/FX and TX/SX (-00, -10, 20, 30) The LED functions
ii FCC Radio Frequency Interference Statement MediaConverter/1 and /4 This equipment has been tested and found to comply with the limits for a Class
16 Installation Troubleshooting The following information assists in troubleshooting the Modular Media Converters: • During installation, first test t
17 Rackmount Instructions Elevated Operating Ambient If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the ra
18 Specifications Operating Temperature +32°F to +122°F (0°C to +50°C); 5% to 95% (non-condensing), 0 – 10,000 ft. altitude Storage Temperature -13°F
19 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, whi
20 WARNING! Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage. Do not handle these compone
21 Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The produc
1 International Headquarters B&B Electronics 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 — General Fax (815) 433-5105 Websi
iii LIMITED LIFETIME WARRANTY Effective for products of B&B Electronics shipped on or after May 1, 2013, B&B Electronics warrants that each su
iv Table of Contents FCC Radio Frequency Interference Statement ... ii Limited Lifetime War
1 About the Modular Media Converters The Modular Media Converter Series includes modules that convert copper to single-mode or multi-mode fiber at Eth
2 About McLIMs McLIMs (Media Converter Link Interface Modules) are 100 Mbps Fast Ethernet modules which provide a single-conversion between 100Base-TX
3 Board Diagrams and Jumper/Switch Settings NOTE To determine which board diagram matches the module (-20, -30, -40, -50, etc.), compare the jumper
4 Media Converter Jumper/DIP Switch Configuration Table Module/Board Feature Jumper Position ON (pins) OFF (pins) Factory Default McPIM TP/FO (-20)
5 Twisted Pair Crossover/Straight-Through Connections Whether using crossover or straight-through CAT5 twisted pair cabling, all Switching Modules wil
Comentarios a estos manuales